As highlighted in the June 2014 issue (p72), it is very important to gather knowledge of the application and the most severe circumstances in which an off-highway HVAC system will operate. When operating in the Middle East, USA or the south of Europe in particular, the system will be challenged!
In order to ensure it is designing the right system, SNDC’s engineering team therefore invariably goes through four steps, beginning with the heat load prediction (HLP) program. In order to maintain the comfort condition inside the cab, an HVAC system’s cooling and heating capacity unit – including air intake (filter system) and air distribution (cab dashboard and ducts) – has to deliver, despite being challenged by a constant heat load from the outside.
Data from the 3D cab (windows and walls) and the material used (insulation and glass coefficient) is then entered in the HLP program. The extreme conditions of use, including temperature, windspeed and humidity will, together with the desired comfort temperature inside the cab, lead to a calculation of: the heat entering the cab in summer or leaving it in winter, via conduction and convection; the fresh air intake; sun and machine radiation (from the engine compartment and hydraulic system) etc; and human body heat and the resulting humidity generation.
The values obtained under those conditions will be the minimum HVAC system expected performance. Note, however, that when converted to the IMACA standard (used to compare units tested under the same conditions), the air in +35°C/50% RH for air-con or -20°C for heater will provide a higher kW result than calculated with cab equilibration at 25°C or lower.
HVAC design process
With the required performance now specified, the coils (evaporator, heater and condenser) can then be designed. On the basis of the available HVAC unit envelope, the thermal heat exchanger (THE) software determines the dimensions and characteristics of all coils, although it primarily takes into account the flow conditions of the air crossing the coil, using data provided by the HLP results.
The sheer variety of possible coil patterns, tube sizes, circuits, configurations and fin spacing requires a special emphasis to be placed on design. For an evaporator, the main conditions to consider include:
The third step involves the use of airflow simulation (AFS) software, which provides a good picture of HVAC acoustics and performance in terms of driver comfort, including in-cab air distribution, temperature balance, and windscreen defrosting and defogging.
The AFS permits full analysis of the airflow loop using a 3D design file. The tool ensures that each air loop component, such as coil heater, coil evaporator, casing, air flaps, air deflectors, ducts and louvers are properly sized and provide acceptable pressure drop.
Of course, knowing the required performance (Step 1), developing high-quality exchangers (Step 2) and ensuring the air distribution quality (Step 3) are all necessary steps – but it should not be forgotten that the refrigerant loop plays one of the most important roles in an HVAC system.
The refrigerant flow prediction (RFP) software used by SNDC takes into account each component of the loop, and checks that:
Clearly, then, SNDC’s 28 years of experience in HVAC systems for OEM markets is invaluable. These two articles have been designed to educate readers on the complexity of HVAC, because building an HVAC system is rather like being a one-man band: knowing the music is not enough – you must also know how to play several instruments. This is the price of driver cab comfort!
Jean Marc Guittard, president, founded SNDC in 1986
The world’s leading publication for industrial and off-road vehicles in construction, agriculture and mining
Les centrales ECOCLIM assurent le recyclage et la recharge en une seule manipulation.
La prochaine édition du salon EQUIP AUTO s’installera du 18 au 22 octobre 2022 dans les halls 1, 2.2 et 3 du Parc des expositions de Paris Porte de Versailles. L’évènement de l’après-vente et des services à la mobilité conserve son rythme biennal et s’inscrit désormais dans un nouveau calendrier, à l’automne, les années paires.
SNDC à le plaisir de vous annoncer sa participation à EQUIP’AUTO ON TOUR 2021 qui aura lieu à TOULOUSE au MEETT. Nous vous attendons nombreux !
L’entreprise de Haute-Garonne SNDC, propriétaire de la marque Ecoclim, va moderniser ses installations pour tripler sa capacité de production d’ici deux ans et solidifier son rang de spécialiste français du traitement des fluides frigorigènes.